ZIVE BP/MP Series |
|
ZIVE MP5HC |
Hardware
High compliance voltage multichannel potentiostat/galvanostat/impedance analyzer
Control voltage range: ±10V, ±1V, ±100mV
Control current range: 100pA ~ 1A (100pA with gain, 11 ranges)
Compliance voltage: ±40V
Channel expandable up to 32 channels
|
|
|
|
|
|
|
|
|
응용 분야
Application
- Corrosion
- Coating
- Material testing
- Other low conductivity Echem experiments
Features
- High compliance voltage multichannel potentiostat/galvanostat/impedance analyzer
- Voltage range : ±10V
- Current range : 11 ranges
- 10nA to 1A - 100pA with gain
- Compliance voltage range : ± 40V
- 8 fully independent channels with 14 EIS techniques capability including multisine
- Multichannel FRA function to control an external electronic load or 3rd party potentiostat/galvanostat is available as standard
- Current interrupt IR measurement
IR compensation available(dynamic, positive feedback)
- Voltage pulse or current pulse charge/discharge test(GSM,CDMA etc.), sine wave function for ripple simulation in battery test package and pulse plating available
- High speed data sampling time
-2usec or 3usec depending on data point numbers
- 3 measurement/control voltage ranges & 11 measurement/control current ranges
- Internal 542,000 data point storage and continuing experiment regardless of PC failure
- K-type thermocouple input for temperature measurement as standard
- 1 auxiliary analog output
- 3 digital outputs & 2 digital inputs
- External booster(ZB series) interface for high current application
- Inclues basic software, Impedance/Corrosion/Battery/Echem analysis software packages
- Min. number of channels : 2 channels, channel expandable up to 32 channels
- Can use EIS data analysis software, ZMANTM and DC data analysis software IVMANTM without purchasing license code
- Free software upgrade
Experimental Techniques
Basic techniques
- Potentiostatic
- Galvanostatic
- Double step potentiostatic
- Double step galvanostatic
- OCP measurement
- Potential sweep
- Current sweep
- Cyclic voltammetry
- Fast potential sweep
- Potentiostatic Ru measurement
- Galvanostatic Ru measurement
Advanced Software Package(Included)
- EIS software package(EIS)
- Potentiostat EIS - Galvanostatic EIS - Pseudo galvanostatic EIS - OCP* EIS - Potentiodynamic PEIS - Galvanodynamic GEIS - Poteniodynamic HFR - Galvanodynamic HFR - Potentiostatic HFR monitor - Galvanostatic HFR monitor - Multisine potentiostatic EIS - Multisine galvanostatic EIS - Intermittent potentiostatic EIS - Intermittent galvanostatic EIS (*) The system measures open circuit potential before each frequency change
and applies AC sine wave on this potential.
- Corrosion software package(COR)
- Tafel(Tafel experiment) - Rp(Polarization resistance) - RpEc trend - PDYN(Potentiodynamic) - CYPOL(Cyclic polarization resistance) - GDYN(GalvanoDynamic) - Reactivation - Galvanic corrosion - Potentiostatic ECN - Galvanostatic ECN - ZRA mode ECN
- Energy software package(BAT)
a) Battery test technique - CC/CV testforcycle life test of lithium battery - CC/CC tet forcyclelifetestofNiCd or NiMH battery - Discharging test - EVS(electrochemical voltage spectroscopy) - Variable scan rate CV - Potentiostatic IV curve - Galvanostatic IV curve - Steady state CV - PITT(Potentiostatic intermittent titration technique) test - GITT(Galvanostatic intermittent titration technique) test - Pulse mode is available for GSM & CDMA profile. Pulse shape profile can be measured by user's demand. b) Control mode - Charge : CC, CC-CV, pulse, sine wave - Discharge : CC, CP, CR, pulse, sine wave c) Cut-off condition - Time, voltage, current, power, auxV etc. - Various battery charge/discharge test is available including pulse discharge for GSM, CDMA application
- Electrochemical analysis software package(EAS)
a) Step techniques - CA(Chronoamperometry) - CC(Chronocoulometry) - CP(Chronopotentiometry) b) Sweep techniques - LSV(Linear sweep voltammetry) - SDV(Sampled DC voltammetry) - Fast CV - Fast LSV c) Pulsed techniques - DPV(Differential pulse voltammetry) - SWV(Square wave voltammetry) - DPA(Diff.pulse amperometry) - NPV(Normal pulse voltammetry) - RNPV(Reverse normal pulse voltammetry) - DNPV(Differential normal pulse voltammetry)
Options
|
|
|
|
|
|
|
|
|
|
|
|