SI Software for WBCS |
Software for WBCS3000 series
32bit multi-tasking
Virtual control panel
Tool bar: quick access for easy operation
User friendly software
To use this software, SIF board is required.
|
|
|
|
|
|
|
|
|
응용 분야
Software
- 32bit/64bit OS environment
- TCP/IP communication
- Max. 200 steps
- Max. 10 cutoff(vertex) condition
- Max. 300,000 data point memory on control board
- Single/multichannel control panel
- Various real time plots & universal axis graphs
- Data backup function
- WYSIWYG graphics
- User friendly software
- Predefined technique menu
Electroanalytical
techniques
- Cyclic voltammetry - Linear
sweep voltammetry
- Chrono-amperometry
- Chrono-coulometry
- Chrono-potentiometry
Corrosion measurement - Tafel
plot
- Potentiodynamic
- Potentiostatic - Galvanostatic
- Cyclic
polarization
- Ecorr vs.
time
- Linear
polarization resistance
- Energy Test
- CC/CV (Lithium battery) test menu
- CC/CC (NiCd(NiMH) battery) test menu
- Steady state CV
- Pstat IV curve
- Gstat IV curve
- EVS (Electrochemical voltage spectroscopy) test
- GITT (Galvanostatic intermittent titration technique) test
- PITT (Potentiostatic intermittent titration technique) test
- Schedule editor
• One stop test condition creation/modification
• Multiple input parameters available
• Max. 200 test steps
• Control parameters
- Constant voltage, LastV
- Constant current, LastI
- Constant power
- Constant load
- C-rate
- Voltage scanning, current scanning
- Conditioning potential
- Conditioning current
- Rest
- LastVscan
- CstepV(Staircase Voltage Sweep)
- CstepI(Staircase Current Sweep)
- CC/CV, CL/CV, CP/CV, Crate/CV
- Id, Is control
- Single channel & multichannel control/monitor panel
- Single channel control/monitor panel
- Multichannel control/monitor panel
- Simple monitor
- Real time display: time, voltage, current, channel status
- Channel status color display: charging, discharging, standby,
idle, calibration
- Control type
voltage, current, power, load, rest, C-rate, current scan, voltage scan, conditioning potential, voltage step, current step, rest conditioning, Last I, Last V, OCV, LastVscan, VocScan, ZRA
- Cut-Off (Vertex)
time, voltage, current, dV/dt, dI/dt, percentage capacity (FCC, FCD, LCC, LCD), cycle time, capacity, -dV, power, temperature, Aux voltage, Calc voltage, dT/dt
- Data acquisition setting
time, dV/dt, dI/dt, dT/dt, dV2/dt
- And/Or logic available in cut-off condition
- Virtual control panel
- In virtual control panel, it displays real time graphics (V vs. I, V & I vs. time, V vs. logI etc) to fit its own techniques. It also displays current data and other information of current experiment. - Experiment parameters can be saved or loaded on the virtual control panel. - On experiment running, users can data analysis or other tasking simultaneously. - Nominate data saving folder by user selection - Cell connection check function
- Rea time data monitor
- Displayed test data: status, running time, step number, cycle
number, step time,
current range, current,
voltage, capacity, power, energy, Aux V,
Calc V, temp,
cycle file name, data file name,
and file size.
- Tools
- Data Editor : General data report, Cycle data report
- Data editing
- Data filtering
- Graphics
- Universal graphic function User can set X, Y, Y1 axis variable - User can use this function for running experiment - With re-load button click, the data format can be changed with out data loading.
- File overlay: Max. 20 files - Automatic scaling and manual scale/polarity setting available - Crosshair data pointing displays the data value by mouse click - Caption available on the graph
- Density, specific value display
- Slope calculation function - Grid and pixel/line selection
- Copy to clip board for graphic data - Data conversion only for graph data
- Parameter change without reloading the data file
- Data set On/Off: Data can be visible or invisible by selecting/deselecting the data set
- Rest step data hidden function
- Advanced graph setting
- Safety limit & fail check function
- To protect hardware, this system stops the experiment run automatically when detect
the any value over hardware specification or user defined safety value.
- It also stops the experiment running when the control value is different from measured
value by wrong connection or abnormal reference electrode etc.
- If the user tries to close the program by mistake operation, the program refuses this operation.
- This system monitor the cell voltage and if the voltage value is too small, then warning message
will be display to protect wrong cell connection.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WBCS Introduction & SI software |
WBCS3000 Introduction |
|
|
|
|
WBCS mid power type |
WBCS3000S |
|
|
|
|
WBCS low power type |
WBCS3000Ls32 |
|
|
|
|
WBCS high power type |
WBCS3000HP |
|
|
|
|
|
|
|